Skip to content

Power Supply Examples

Complete power supply designs for various applications.

Examples

Example Description Difficulty Status
Isolated DC-DC Flyback, Forward, Half-bridge Intermediate Placeholder
PFC Converters Single and bridgeless PFC Intermediate Placeholder
LLC Resonant High-efficiency resonant Advanced Placeholder
DAB Converter Dual Active Bridge, bidirectional Advanced Placeholder

Quick Reference

Topology Selection by Power

Power Range Topology Typical η
1-30W Flyback 85-90%
30-150W Flyback/Forward 88-92%
100-500W Forward/Half-bridge 90-94%
300W-3kW Full-bridge/LLC 92-96%
500W-5kW LLC Resonant 94-97%
1-50kW DAB (bidirectional) 95-98%

Topology Comparison

Feature Flyback Forward LLC DAB
Isolation Yes Yes Yes Yes
Bidirectional No No No Yes
Soft switching No No ZVS ZVS
Complexity Low Medium High High
Best for Low power Medium High η Energy storage

Key Applications

Application Power Topology
Phone charger 5-20W Flyback
Laptop adapter 65-100W Flyback/LLC
Server PSU 500-2000W LLC
EV OBC 3-22kW PFC + LLC/DAB
Energy storage 10-100kW DAB
DC microgrid 5-50kW DAB

Design Considerations

Aspect Flyback Forward LLC DAB
Component count Low Medium High High
Transformer Gap (stores energy) No gap Resonant tank HF isolation
Efficiency Medium Good Excellent Excellent
EMI Higher Medium Lower Lower
Control Simple Simple Complex Medium

Efficiency Breakdown

LLC Resonant (1kW example)

Loss Value %
Primary switching 5W 0.5%
Transformer 10W 1.0%
Secondary rectification 15W 1.5%
Control 5W 0.5%
Total 35W 3.5%
Efficiency 96.5%